UC-AP USB 800kg aerometal contruction rectangle elevator cabin mounting compression load cell
Rated load :800kg rectangle under elevator cabin mounting compression load cell
Description:
SUMMIT Elevator Cabin load cell sensors UC-AP are supplied with their own integral silent-block rubber mounting arrangement to avoid vibration transmission, and specifically designed for installation below the elevator & lift car. They easily mount under the cab and are extremely accurate, The UC-AP series load cell sensor are designed for use with new passenger lift up to 3200kg load (4pcs) in parallal.
Note: Under cab sensors UC-AP series are not recommended for lift modernization or retrofit.
Features:
Anodised aluminium construction
Up to 4x800kg: 3200kg load (4 sensors)
High accuracy,USB interface or plug
Individual sensor can be replaced
Perfect for new installations
Load cell for installation under elevator cabin.
Mounted on a silent-block pad that avoids the transfer of vibrations .
Connected to the unit control of the OMS-560 series and able to install a quantity of 4 cells in parallel, and max up to 8pcs load cell UC-AP
Adjustable locking screw to adjust the unevenness of the bottom of the car during assembly
Model |
UC-AP |
Range |
800KG |
Rated Output |
2.0±0.02%mV/V |
Excitation Voltage |
≤15VDC |
Input Impedance |
1030±10Ω |
Out Impedance |
1000±2Ω |
Insulation Impedance |
≥5000MΩ |
Safe Overload |
150%F.S |
Ultimate Overload |
200%F.S |
Error |
±0.5%F.S |
Repeatability |
±0.5%F.S |
Null Balance |
±1%F.S |
Product Creep |
±0.05%F.S/30min |
Temperature Effect |
±0.02%F.S/10ºC |
Opperation Temperature |
-30~70ºC |
Material |
Aerometal |
Protect Class |
IP67/IP68 |
Cable Length |
2.5M |